Vivanco UNIVERSAL SWITCHMODE AC TO DC MAINS ADAPTERS WITH USB CHARGING FUNCTION Uživatelská příručka Strana 77

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 118
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 76
System Operation
© 2008 Microchip Technology Inc. DS70320B-page 73
A power meter is capable of measuring the input Power Factor of the SMPS AC/DC
Reference Design and also the Total Harmonic Distortion (THD) on the current drawn
by the system.
Using a programmable AC source will enable the user to evaluate the system
performance over the entire range of input voltage (85V-265V, 45Hz-65Hz).
4.2.2.2 OUTPUT PERFORMANCE TESTING
The SMPS AC/DC Reference Design can be loaded using DC electronic loads. A
number of output parameters can be tested by connecting oscilloscope probes to the
output terminals. Some of the parameters that can be tested are:
Output Ripple Voltage
Load Regulation
Transient Response
Step-Load Response
Fault Shutdown Delay
Zobrazit stránku 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 117 118

Komentáře k této Příručce

Žádné komentáře